When it comes to protecting a building, design is just the beginning—performance must be verified in the field. Our building envelope testing services confirm that systems are performing correctly and operating as intended against water, air, and structural challenges. From podium decks and below-grade waterproofing to curtain walls and fenestration, our accredited testing provides defensible results that reduce liability and give all stakeholders peace of mind.
Performance testing of fenestration systems for air, water, and structural integrity.
Validation of curtain wall performance using accredited FGIA standards.
Testing storefront systems for water resistance and air leakage control.
Accredited performance testing for skylight assemblies under real-world conditions.
Pinpoint verification of membrane integrity with electronic leak detection technology.
Infrared thermal imaging to detect moisture, air leaks, and insulation gaps.
Aerial imagery documenting envelope conditions and construction progress.
Consistent progress documentation with UAV imaging and reporting.
Independent verification of horizontal waterproofing flood tests for podiums and plazas.
Advanced diagnostic services for complex or unique envelope conditions.
Even small deficiencies in waterproofing or glazing assemblies can cause major financial loss. Leaks, condensation, and air infiltration not only damage interiors, disrupt people and businesses but also shorten the building’s lifespan, increase operational costs and fuel disputes. By implementing building envelope testing services early and throughout construction, we provide objective verification that critical systems meet FGIA/AAMA standards.
Windows and glazing systems are among the most vulnerable parts of any building envelope. Our window water penetration testing evaluates how installed fenestration responds under simulated wind and rain conditions. Using ASTM E1105 and AAMA 502/AAMA 503 standards, we verify installation quality, sealant performance, and drainage paths. These tests confirm the system resists water intrusion, thereby protecting interior finishes and ensuring occupant comfort.
Horizontal waterproofing systems, such as podium decks and plaza assemblies, face unique risks. We observe, monitor and document simulated ponded water conditions to evaluate membrane integrity and drainage performance. With controlled flood tests before occupancy, we help to ensure podium and plaza waterproofing can withstand real-world conditions, preventing costly leaks that often go undetected until it’s too late.
Uncontrolled air leakage impacts more than just energy efficiency—it can drive moisture into assemblies, cause condensation, increase operation costs and reduce overall performance. Our air leakage testing follows ASTM E783 and AAMA 502/AAMA 503 standards to measure how well fenestration and envelope systems resist air infiltration under pressure. These results help owners achieve energy compliance, lower utility costs, and maintain healthier indoor environments.
Storefronts and curtain walls demand specialized evaluation due to their size, complexity, and exposure to wind-driven rain. Our curtain wall performance testing follows AAMA 503 and 501.2 procedures to assess water resistance, air infiltration and integration with adjacent systems. By validating curtain wall performance under real pressure, we protect against long-term failures that are expensive and disruptive to fix after occupancy.
Testing without documentation leaves stakeholders exposed. Every test we perform is supported by detailed reporting, photographic evidence, and defensible records. This performance documentation satisfies warranty as well as insurance requirements and provides owners with peace of mind that their building has been constructed and tested to the highest standards.
Comprehensive, FGIA/AAMA-compliant test results that assist with disputes, warranty, and insurance claims.
Detailed photographic documentation and field notes that capture every step of testing and confirm installation performance.
Clear records that provide long-term assurance your building envelope was tested, verified, and built to last.
Our field testing processes adhere to recognized commissioning methodologies used in federal buildings, including water penetration testing per ASTM E1105 and field nozzle tests per AAMA 501.2, as outlined in the NIBS ‘Building Enclosure Commissioning’ guide.
From mixed-use towers to institutional campuses and office buildings, clients choose our building envelope testing services because we deliver speed, accuracy, and proven results. Developers gain confidence that investments are protected, architects reduce liability by verifying design intent, and contractors keep schedules on track by resolving issues before they escalate.
Don’t leave your project’s success to chance. Our accredited building envelope testing services provide the independent verification you need to confirm systems are watertight, airtight, and built to last.